Enerplus – Freda Lake Oil Battery

The original 01-31 Freda Lake Oil Battery was built in 1968 and was an aging facility that needed replacing due to safety and environmental reasons. It was decided to build a new oil battery, rather than upgrade the existing one. Installed equipment included:

  • 10’ x 40’ FWKO
  • Move Existing / Refurbished Treater
  • Two (2) 2000 bbl Water Tanks
  • Two (2) 1000 bbl Oil Tanks
  • One (1) Recycle / Transfer Skid
  • One (1) Instrument Air Package
  • One (1) Flare Stack c/w Auto Ignition
  • One (1) Flare Knockout Drum (FKOD)
  • One (1) MCC Building
  • One (1) Office / Control Room
  • One (1) Water Injection Pump Skid c/w two REDA pumps
  • Associated piping, valves, and fittings
  • Pipelines to existing header systems
  • Demolition and cleanup of existing 01-31 site