Enerplus – Cadogan 10-14 Battery Expansion

Gas Liquids Engineering Ltd. (GLE) provided complete EPCM services for an expansion of the 10-14 Cadogan oil battery located in Southeast Alberta. Project scope included:

  • Regulatory updates to change the maximum licensed inlet water rate from 750 m³/d to 1800 m³/d and licensing for new injection pumps, inlet compression, and new flare stack
  • Two (2) 1000 bbl water and skim storage tanks c/w new berm sized for six (6) tanks
  • A water injection skid with a capacity of 1800 m³/d with:
    • Two (2) booster pumps capable of 3600 m³/d each
    • One (1) water injection pump capable of 1800 m³/d
    • Skid sized to accommodate a second water injection pump for future upgrade
  • A new electric driven gas compressor with a design flow rate of 0.7 MMSCF/d, and removal of existing compressor
  • A second MCC building
    • One (1) 400 hp VFD, with room for additional 400 hp VFD for future upgrade
    • One (1) 100 hp VFD
  • A high pressure emergency flare sized for 9 MMSCF/d
  • Piping upgrades
  • Structural steel and civil work
  • Electrical service upgraded from 400 A to 1000 A

On this website we use first or third-party tools that store small files (cookie) on your device. Our cookies are used to generate navigation usage reports. You have the right to choose whether or not to enable these cookies. By enabling these cookies, you help us to offer you a better experience. Cookie policy